0%

When the Extinguisher Test switch is held in the 1 or 2 position, 3 lights illuminate indicating:

Correct! Wrong!

A dual fire detector loop is installed in the main wheel well

Correct! Wrong!

A single fire detector loop is installed in the main wheel well. As the temperature of the detector increases to a predetermined limit, the detector senses a fire condition. The WHEEL WELL fire warning remains illuminated until the temperature of the detector has decreased below the onset temperature.

There are two fire detection loops installed on the APU.

Correct! Wrong!

A single fire detection loop is installed on the APU.

What is the power source for the Engine Overheat and Fire Detection?

Correct! Wrong!

Holding the TEST switch to the FAULT/ INOP position:

Correct! Wrong!

The engine fire switches are normally locked down to prevent inadvertent shutdown of an engine:

Correct! Wrong!

Pulling the engine fire warning switch up:

Correct! Wrong!

During an OVHT/FIRE test the No 1. Fire Handle light and associated overheat light do not illuminate. What does it indicate?

Correct! Wrong!

APU Fire Detection - As the temperature of the detector increases to a predetermined limit, the detector senses a fire condition. The APU fire switch remains illuminated until the temperature of the detector has decreased below the onset temperature.

Correct! Wrong!

The APU Horn Cutout switch in the main wheel well will silence:

Correct! Wrong!

Advertisement

The power source for Engine Fire Extinguishing is the:

Correct! Wrong!

The Engine Fire Extinguisher system contains:

Correct! Wrong!

If the DETECTOR FAULT light is illuminated (amber), a minimum of one loop in one or both cargo compartments have failed.

Correct! Wrong!

BOTH loops in one or both cargo compartments have failed.

The power source for the APU Fire Detection is the:

Correct! Wrong!

Holding the TEST switch to the OVHT/FIRE position with AC on the busses will illuminate the:

Correct! Wrong!

Cargo compartement smoke detection is powered by:

Correct! Wrong!

Cargo compartment fire extinguishing is powered by the hot battery bus.

During normal operation as a dual loop system, with the OVHT DET switch in NORMAL, an alert is initiated only if one of the detector elements in Loop A and one of the detector elements in Loop B signal an overheat or fire condition.

Correct! Wrong!

Illuminated (amber) FAULT with the overheat detector switch in NORMAL it indicates both detector loops for an engine have failed. With the overheat detector switch in A or B it indicates the selected loop for an engine has failed. MASTER CAUTION and OVHT/DET system annunciator lights also illuminate.

Correct! Wrong!

MASTER CAUTION and OVHT/DET system annunciator lights do NOT illuminate.

The system contains a fault monitoring circuit. If one loop fails with the OVHT DET switch in NORMAL, that loop must be manually deselected and the remaining loop functions as a single loop detector.

Correct! Wrong!

If one loop fails with the OVHT DET switch in NORMAL, that loop is automatically deselected and the remaining loop functions as a single loop detector.

Engine Overheat and Fire Detection - If the OVHT DET switch is positioned to A or B, the system operates as a single loop system. The non-selected loop is not monitored. If the selected loop fails, the FAULT light illuminates and the system is inoperative.

Correct! Wrong!

Advertisement

The APU horn in the main wheel well can be silenced by:

Correct! Wrong!

All switches on the Fire Panel are in their normal positions. The TEST switch is then held in the OVHT/FIRE position and all normal test indications are observed. The FAULT light is also observed to be illuminated which would mean that:

Correct! Wrong!

In case of Cargo Fire, the Cargo Fire (FWD / AFT) Warning Lights are illuminated red.

Correct! Wrong!

If smoke / fumes are uncontrollable, the crew is supposed to descent to the lowest safe altitude and at 14000 or below, the PRESSURIZATION MODE SELECTOR should be positioned to MAN while the OUTFLOW VALVE switch should be opened. What is the main cause of the OUTFLOW VALVE operation?

Correct! Wrong!

The outflow valve can take up to 20 seconds to open.

The Engine Overheat and Fire Protection system has:

Correct! Wrong!

Illumination of the APU DET INOP light will also cause the MASTER CAUTION and OVHT/DET annunciator lights to illuminate.

Correct! Wrong!

Main wheel well fire protection consists of fire detection powered by the:

Correct! Wrong!

Placing the TEST switch in the FAULT / INOP position tests:

Correct! Wrong!

After a wheel well fire, if the landing gear must be retracted for airplane performance, leave the landing gear extended for ___ minutes after the WHEEL WELL fire warning light has extinguished.

Correct! Wrong!

With the OVHT DET switch in the B position:

Correct! Wrong!

Advertisement

The Engine Fire Extinguisher system contains:

Correct! Wrong!

APU fire protection consists of:

Please select 2 correct answers

Correct! Wrong!

Some of the indications for an engine fire warning are MASTER CAUTION & OVHT/DET annunciator lights, the ENG OVERHEAT light, the Master FIRE WARN lights and the red fire switch light. What are the other indications?

Correct! Wrong!

Boeing 737 MAX - Fire Protection