Airbus A340 - Fire Protection and Detection
If the ENG FIRE pb is depressed:
Correct!
Wrong!
A fire has been detected on engine 1. ENG 1 FIRE p/b and FIRE light of ENG 1 MASTER will extinguish:
Correct!
Wrong!
"DISCH" comes on amber when the corresponding fire extinguisher bottle has lost pressure.
Correct!
Wrong!
The APU fire extinguishing system includes:
Correct!
Wrong!
For lavatory smoke detection, each lavatory is equipped with:
Correct!
Wrong!
If a smoke has been detected in one of the lavatories:
Correct!
Wrong!
On the CARGO SMOKE overhead Panel, when does SQUIB illuminate white?
Correct!
Wrong!
Fire extinguishing. Which statement is true?
Correct!
Wrong!
Smoke has been detected in the FWD cargo compartment. The pilot has pushed the FWD AGENT pb. Bottles 1 and 2 have discharged:
Correct!
Wrong!
Engine fire protection is provided by 2 detection loops which provide informations to a computer (FDU). Which statement about these loops is right?
Correct!
Wrong!
Advertisement
Broadband system - The smoke detection system consists of 2 optical smoke detectors located in the ventilation system of the corresponding Broadband System in the avionics compartment. When smoke is detected, the smoke light on the PAX BBAND pb-sw on the overhead panel comes on red along with the smoke ECAM warning.
Correct!
Wrong!
APU Fire - The presence of the red disc on the left side of the aircraft fuselage indicates:
Correct!
Wrong!
When the SMOKE LAVATORY SMOKE red ECAM message appears in the cockpit:
Correct!
Wrong!
Smoke has been detected in the AFT cargo compartment. The pilot has pushed the AFT AGENT p/b and bottle 1 has discharged. The bottle 2 :
Correct!
Wrong!
Which of the following statements is true?
Correct!
Wrong!
What does an amber ECAM warning SMOKE DET FAULT mean?
Correct!
Wrong!
The fire and overheat detection system of the Main Landing Gear (MLG) consists of 2 fire detection loops (A and B), 2 fire detectors, and a Fire Detection Unit (FDU).
Correct!
Wrong!
There are 4 fire detectors not 2.
Cargo fire protection is provided by:
Correct!
Wrong!
The avionics smoke warning triggers, if:
Correct!
Wrong!
AGENT pb on Fire overhead panel is operative when:
Correct!
Wrong!
Advertisement
When an APU fire is detected on ground, the APU fire light on the External Power Control Panel comes on and in addition:
Correct!
Wrong!
The fire protection system provides:
Correct!
Wrong!
What does an amber ECAM warning ENG 1 FIRE DET FAULT mean?
Correct!
Wrong!
The smoke detection system of the cargo compartments consists of Smoke detectors, that are housed:

Correct!
Wrong!
When smoke is detected in the avionics compartment:
Correct!
Wrong!
Airbus A340 – Fire Protection and Detection